Snap-in electrolytic capacitor reliability index CADAA for military & defense

  • There are reliability indicators, and there are five levels of failure rate(λ≤1×10-5)
  • It meets the environmental requirements of vibration, low pressure, humidity resistance and other environmental requirements of the national military standard GJB603-88
  • It is suitable for filtering, coupling and bypassing in electronic circuits in aerospace, aviation, alpine, high altitude and ocean

Empty tab. Edit page to add content here.

FEATURES

◆ 105°C, 1000 hours assured.
◆ Standard micro miniature size with 5mm height.
◆ RoHS Compliance

Item characteristic
Operating temperature range -55℃~+105℃
Rated voltage range 10V~500V
Nominal capacitance range 47μF~68000μF
Allowable       deviation       of                         nominal capacitance(25℃,100Hz) M(±20% )
DC leakage current(25℃,5min) I≤0.02CRUR(μA)

CR:Nominal capacitance(μF);UR:Rated voltage(V)

 

Dissipation factor tgδ(25℃,100Hz)

UR(V) 10 16 25 35 50 63 80 100 160~450 500
tgδ(≤) 0.20 0.18 0.15 0.12 0.10 0.10 0.10 0.10 0.15 0.20
Products with capacities greater than 1500μF,Each increase1000μF,The dissipation

factor    increases0.02。

Temperature Characteristics

(100Hz)

Impedance ratio Z-55℃/Z+25℃≤15
Rate   of change

in capacitance

(C+25℃-C-55℃)/C+25℃≤20%(≤40%(500V))

(C+25℃-C-40℃)/C+25℃≤10%(≤20%(500V))

 

 

 

durability

The  rated  voltage  with  ripple  current  is  applied  at  105°C   for  2000h,  and after

recovery for 24h, the rated voltage with ripple current is tested at room temperature (25°C±5°C), and its electrical performance is in accordance with the test :

Rate of change in capacitance ≤±15% Initial measurements
The dissipation factor tgδ ≤150% Initial prescriptive value
DC leakage current ≤Initial prescriptive value
 

 

Store at high temperatures

After being left at 105 °C for 500h and recovered for 24 hours, the electrical performance was tested at room temperature (25 °C±5  °C). :
Rate of change in capacitance ≤±15% Initial measurements
The loss angle tangent tgδ ≤200% Initial prescriptive value
DC leakage current ≤200% Initial prescriptive value
Please enable JavaScript in your browser to complete this form.