Radial electrolytic capacitor low ESR CABBA for military & defense
- 7mm height and small model, suitable for high-density assembly of electronic circuits.
- Military products meet environmental requirements such as vibration and low air pressure.
- Military products can be supplied according to the “seven specialized” level, and can also be supplied according to the “general army”
- It is suitable for filtering, energy storage and bypass in electronic circuits in aerospace, aviation, alpine, high altitude and ocean.
Itme | characteristic | |||||||||||||
Operating temperature range | -40℃~+85℃ | |||||||||||||
Rated voltage range | 6.3V~63V | |||||||||||||
Nominal capacitance range | 0.1μF~330μF | |||||||||||||
Allowable deviation of nominal
capacitance (25°C, 120Hz) |
M(±20% ) | |||||||||||||
DC leakage current(25℃,5min) | I≤0.01CRUR or 3 (whichever is greater)
CR: Nominal Capacitance (F); UR: Rated voltage (V) |
|||||||||||||
The loss angle tangent tgδ (25℃,120Hz) |
||||||||||||||
UR(V) | 6.3 | 10 | 16 | 25 | 35 | 50 | 63 | |||||||
tgδ(≤) | 0.24 | 0.20 | 0.16 | 0.14 | 0.12 | 0.10 | 0.10 | |||||||
Temperature characteristics (impedance ratio, 120Hz) |
||||||||||||||
UR(V) | 6.3 | 10~16 | 25~63 | |||||||||||
Z-40°C/Z+25°C | ≤7 | ≤5 | ≤4 | |||||||||||
durability |
The rated voltage with ripple current is applied at 85°C for 1000h, and after
recovery for 24h, it is tested at room temperature (25°C±5°C), and its electrical performance conforms to: |
|||||||||||||
Rate of change in
capacitance |
≤± 20% of the initial measurement | |||||||||||||
Loss tangent tgδ | ≤ 200% of the initial specified value | |||||||||||||
DC leakage current | ≤ initial prescriptive value | |||||||||||||
Store at high temperatures |
After storage at 85°C for 500h and recovery for 24h, it was tested at room
temperature (25°C±5°C), and its electrical properties conformed to: |
|||||||||||||
Rate of change in
capacitance |
≤± 20% of the initial measurement | |||||||||||||
Loss tangent tgδ | ≤ 200% of the initial specified value | |||||||||||||
DC leakage current | ≤ 200% of the initial specified value |