Radiales Electrolytic capacitor reliability Index Cabbc ad militum & defensio
- Sunt fidem Indicatores, et quinque-gradu defectum rate (λ≤1×10-5).
- Minimum ultrices current, ultra-low impedimentum, ultra-longam vitam
- Occurrit environmental requisitis vibrationis, humilis pressura, humiditas resistentia et alia requisita environmental vexillum militaris nationalis GJB603-88
- Convenit ad eliquare, copulare et bypassing in electronic circuitus in aerospace, aviation, alpine, alta altitudo et Oceanum
| item | proprium | |||||||
| Operans temperatus range | -55~+105℃ | |||||||
| Rated voltage range | 10V~100V | |||||||
| Nominal facultatem range | 22µF~1000µF | |||||||
| Deviatio nominis licita
capacitas (25N ° C, 120HZ) |
T(-10%~+50%) | |||||||
| DC lacus current(25℃,5min) | I≤0.006CRUR or 1 (Quicquid est maior)
CR: Nominal Capacitance (F); UR: Rated voltage (V) |
|||||||
|
Angulus jacturae tangens tgδ(25℃,120Hz) |
||||||||
| UR(V) | 10~25 | 32~63 | 100 | |||||
| tgδ(≤) | 0.13 | 0.08 | 0.07 | |||||
| Temperatus indoles (impedimentum ratio, 120HZ) | ||||||||
| UR(V) | 10~25 | 32~50 | 63~100 | |||||
| Z-55°C/Z+25°C | 15 | 10 | 21 | |||||
|
firmitatem |
Aestimatae intentionis applicatur ad 105°C pro 2000h, et post convaluisset 24h *,
electrica observantia de rated voltage (25°C±5°C) probata ad locus temperatus |
|||||||
| Rate mutationis in capacitate | ≤± 20% primae mensurae | |||||||
| Angulus amissus tangens tgδ | ≤ 150% ad valorem certa initial | |||||||
| DC lacus current | ≤ initialis valorem | |||||||
|
Condite in altum temperaturis |
Post actarum ad 105 °C for 500 horas et recuperandi 24 horulus, the
proprietatibus electrica duorum temperaturis (25 °C±5 °C) sunt probata, ac electrica proprietatibus conformatur: |
|||||||
| Rate mutationis in capacitate | ≤± 10% primae mensurae | |||||||
| Angulus amissus tangens tgδ | ≤ 115% ad valorem certa initial | |||||||
| DC lacus current | ≤ 200% ad valorem certa initial | |||||||