screw electrolytic capacitor reliability index CAEAC for military & 방어
- Long-life product, with reliability index, five-level failure rate (λ≤1×10-5).
- Screw construction, full range, available for type A and type B fixing, the size can also be customized according to
- It meets the environmental requirements of the national military standard GJB603A-2021 such as vibration, low pressure, and humidity resistance
- It is suitable for energy storage and filtering in the electronic unified circuit of aerospace, 비행, cold, high altitude and ocean.
안건 | characteristic | ||||||
작동 온도 범위 | -40℃ ~ + 105 ℃ | ||||||
Rated operating voltage range | 10V ~ 450V | ||||||
공칭 정전용량 범위 | 470~820000μF | ||||||
Allowable deviation of nominal
정전 용량 |
M(-20%~+20%) (25℃,100Hz) | ||||||
DC leakage current ( 25℃ ,
5min) |
I≤0.01CRUR (μA) or 15mA (어느 쪽이든 적은)
CR: Nominal capacitance (μF); UR: 정격 전압 (V) |
||||||
Loss tangent tgδ (최대) | For details, please refer to the “List of Product Specifications and Technical Parameters”(25℃,
100Hz) |
||||||
Temperature characteristics (100Hz에서, impedance ratio) | UR(V) | 10~35 | 25~ (100) | 160~250 | 350~ (450) | ||
Z-40℃/Z+25℃ | ≤10 | ≤8 | ≤12 | ≤15 | |||
Rated ripple current | For details, please refer to the “List of Product Specifications and Technical Parameters”
(105℃,100Hz) |
||||||
Durability (High Temperature Test) |
The rated voltage with ripple current is applied at 105°C for 5000h, and after recovery for 24h,
the electrical performance is tested at room temperature (25°C±5°C), and its electrical performance conforms to: |
||||||
Rate of change in capacitance | ≤± 20% of the initial measurement | ||||||
DC leakage current | ≤ initial prescriptive value | ||||||
The loss angle is tangent | ≤ 200% of the initial measurement | ||||||
Store at high temperatures |
Left at 105°C for 1000h, after the test, the normal temperature (25°C±5°C) was restored to the
test, and its electrical properties conformed to: |
||||||
Rate of change in capacitance | ≤± 20% of the initial measurement | ||||||
DC leakage current | ≤ 200% of the initial specified value | ||||||
The loss angle is tangent | ≤ 200% of the initial measurement |